- Configuration
- 80 kW DC Fast charger with two CCS2 sockets
- Input AC Supply
- Three Phase, 5 Wire AC Supply (3Ph. + N + PE)
- Nominal Input Voltage
- 415 VAC (+10%, -15%)
- Input Frequency
- 50 Hz
- I/P Power Requirement
- 95 kVA, 160 A
- No Load Power Consumption
- < 38 W
- Energy Transfer Mode
- Conductive
- Charging Mode
- Mode 4
- Regulation
- Controlled voltage charging (CVC) & controlled current charging (CCC)
- O/P Power
- 150 – 1000 VDC, DC charging current up to 200 A
- Operation Mode
- Simultaneous charging: 40 kW from each CCS2 gun. Dynamic load sharing: 80 kW from one CCS2 gun
- Communication (EVSE–EV)
- PLC as per ISO 15118; initial handshaking using PWM on CP line as per IEC 61851-1
- Rate of Charging Current
- Ramp up as per IEC 61851-23 Sec. 101.2.1.3; ramp down as per Sec. 101.2.1.4
- Current Ripple
- < 1.5 A below 10 Hz; < 6 A below 5 kHz; < 9 A below 150 kHz
- Power Backup
- Minimum 45 minutes
- Electrical Protection
- Under voltage, Over voltage, Residual current, Surge protection, Short circuit, Over temperature, Ground fault, Insulation fault, Emergency stop
- Isolation
- Each DC output isolated from each other as per IEC 61851-23 Sec. 7.5.101
- No. of Outputs
- 2 Nos. CCS2 gun cables
- Charging Cable Length
- 5 m
- Display
- 10.1" LCD touch panel with 1024×600 pixels
- Visual Indicators
- LEDs for each outlet indicating gun availability and alarm status
- Visual Information
- Error indication, charge process indication, cabinet temperatures, transaction logs history, alarms history
- User Authentication
- Autocharge, OTP, Remote Start, MIFARE, ISO/IEC 14443A/B
- Charging Information
- Vehicle plugged in/out, output DC energy, time to full charge, duration since start, start & current SOC, vehicle demand (current & voltage), DC output power/voltage/current
- Metering Information
- DC Meter (class 0.5) for output energy & AC Meter (class 0.5) for input supply energy
- Communication Protocol
- OCPP 1.6 J
- Network Connection
- Wi-Fi, SIM, Ethernet
- Rated Power Efficiency
- > 95% at full load
- Power Factor
- > 0.99 at full load
- THD
- < 5% @ full-load output power of 50%–100%
- Operating Temperature
- -5°C ~ +55°C (de-rating characteristics apply after 55°C)
- Storage Temperature
- -15°C ~ +70°C
- Cooling
- Forced air cooled while charging; air ventilated in idle condition
- Operating Noise Level
- < 77 dBA
- Humidity
- < 95% relative humidity, non-condensing
- IP Rating
- IP 54
- Altitude
- 2000 m
- Emergency Push Button
- Simple push button type switch, easily accessible, covered by acrylic
- Dimension (W × H × D)
- 915 mm × 1633 mm × 466 mm — OVERALL